Resource Type

Journal Article 538

Conference Videos 5

Year

2024 1

2023 44

2022 39

2021 41

2020 26

2019 28

2018 12

2017 27

2016 26

2015 20

2014 17

2013 29

2012 17

2011 21

2010 37

2009 19

2008 41

2007 48

2006 12

2005 7

open ︾

Keywords

temperature 61

Air pollution 10

air pollution 8

Low temperature 6

temperature control 6

numerical simulation 5

ozone 5

air quality 4

high temperature 4

simulation 4

temperature field 4

Air pollution control 3

addition 3

fire 3

low temperature 3

temperature distribution 3

Accelerated aging test 2

Air pollution exposure 2

Air quality 2

open ︾

Search scope:

排序: Display mode:

Multidecadal Trends in Large-Scale Annual Mean SATa Based on CMIP5 Historical Simulations and Future

Nan Xing, Jianping Li, Lanning Wang

Engineering 2017, Volume 3, Issue 1,   Pages 136-143 doi: 10.1016/J.ENG.2016.04.011

Abstract: Intercomparison Project Phase 5 (CMIP5) results, multidecadal variations and trends in annual mean surface airtemperature anomalies (SATa) at global, hemispheric, and hemispheric land and ocean scales in the pastthe temporal variability, long-term trend, multidecadal variations, and trends in global annual mean SATaObservational data analysis shows that the multidecadal variations in annual mean SATa of the land andHowever, SATa over SH land show an increase during the 1945-1970 period, which differs from the other

Keywords: Surface air temperature anomalies (SATa)     Multidecadal trend     Coupled Model Intercomparison Project     Phase    

“Partial pressures” of humid air in wide pressure and temperature ranges

Zidong WANG, Hanping CHEN, Shilie WENG

Frontiers in Energy 2013, Volume 7, Issue 4,   Pages 511-517 doi: 10.1007/s11708-013-0281-7

Abstract: “Partial pressure” in humid air is a question very much concerned by scientists and no satisfactory answerhumid air.The fundamental behaviors of water vapor and dry air are studied in depth in wide pressure and temperatureThe other is that the interaction between dissimilar molecules may be omitted when temperature is above“cutting-off temperature” for unsaturated humid air.

Keywords: partial pressure     Dalton’s partial pressure law     humid air     saturated     unsaturated    

Improvement of part-load performance of gas turbine by adjusting compressor inlet air temperature and

Frontiers in Energy 2022, Volume 16, Issue 6,   Pages 1000-1016 doi: 10.1007/s11708-021-0746-z

Abstract: Moreover, the regulation rules of the compressor inlet air temperature and the IGV opening are studiedThe results show that there is an optimal matching relationship between IGV opening and inlet air temperatureFor the best GT performance of a given load, the IGV could be adjusted according to inlet air temperature, when inlet air temperature is lower than the optimal value with different IGV openings.Further, when the IGV is in a full opening state and an optimal inlet air temperature is achieved by

Keywords: inlet air temperature     inlet guide vane (IGV) opening     part-load     equilibrium running line     gas turbine    

Experimental and kinetic study on laminar flame speeds of ammonia/syngas/air at a high temperature and

Frontiers in Energy 2022, Volume 16, Issue 2,   Pages 263-276 doi: 10.1007/s11708-021-0791-7

Abstract: The laminar flame speeds of ammonia mixed with syngas at a high pressure, temperature, and different

Keywords: ammonia mixed with syngas     laminar flame speed     kinetic model     sensitivity analysis     pathway analysis    

Simulation Research of Temperature Control System in Air-Conditioned Coach

Yu Meichun,Zhang Dengchun

Strategic Study of CAE 2006, Volume 8, Issue 7,   Pages 83-88

Abstract:

The issue studies, in virtue of simulation, temperature control system in air-conditioned coach byAnd PID control can only suit for air conditioning condition with small variation.

Keywords: air-conditioned coach     temperature control     fuzzy control     simulation    

Effect of extrusion temperature on the physical properties of high-silicon aluminum alloy

YANG Fuliang, GAN Weiping, CHEN Zhaoke

Frontiers of Mechanical Engineering 2007, Volume 2, Issue 1,   Pages 120-124 doi: 10.1007/s11465-007-0021-y

Abstract: Al-30Si and Al-40Si are fabricated with air-atomization and vacuum-canning hot-extrusion process.thermal expansion coefficients of the material are measured, and the relationship between extrusion temperaturewith this method is as high as 99.64% of the theory density, and increases with elevating extrusion temperatureAt the same time, thermal conductivity varies between 104-140 W/(m " K); with the extrusion temperature

Keywords: coefficient     hermeticity     temperature     relationship     air-atomization    

An indirect evaporative chiller

Xiaoyun XIE, Yi JIANG,

Frontiers in Energy 2010, Volume 4, Issue 1,   Pages 66-76 doi: 10.1007/s11708-010-0021-1

Abstract: The cold water can be produced almost reversibly under ideal working conditions, with its temperatureinfinitely close to the dew point temperature of the inlet air.The key components of the chiller are an air cooler and a padding tower.The tested temperature of the water produced is below the wet bulb temperature of outdoor air and reachedthe average value of the dew point temperature and the wet bulb temperature of outdoor air.

Keywords: indirect evaporative chiller     dry air     dew point temperature    

Industrial-scale investigations on effects of tertiary-air declination angle on combustion and steamtemperature characteristics in a 350-MW supercritical down-fired boiler

Xiaoguang LI, Lingyan ZENG, Hongye LIU, Yao LI, Yifu LI, Yunlong ZHAO, Bo JIAO, Minhang SONG, Shaofeng ZHANG, Zhichao CHEN, Zhengqi LI

Frontiers in Energy 2021, Volume 15, Issue 1,   Pages 132-142 doi: 10.1007/s11708-020-0803-z

Abstract: Industrial-scale experiments were conducted to study the effects of tertiary air declination angle (TDA) on the coal combustion and steam temperature characteristics in the first 350-MW supercritical down-firedin the lower furnace rose and the symmetry of temperature field was enhanced.The ignition distance of the fuel-rich coal/air flow decreased.The concentration of NO decreased in near-tertiary-air region.

Keywords: supercritical down-fired boiler     industrial-scale experiment     tertiary air declination angle     coal combustion     steam temperature    

The Establishment of a New Air Health Index Integrating the Mortality Risks Due to Ambient Air Pollutionand Non-Optimum Temperature Article

Qingli Zhang, Renjie Chen, Guanjin Yin, Xihao Du, Xia Meng, Yang Qiu, Haidong Kan, Maigeng Zhou

Engineering 2022, Volume 14, Issue 7,   Pages 156-162 doi: 10.1016/j.eng.2021.05.006

Abstract:

A composite Air Health Index (AHI) is helpful for separately emphasizing the health risks of multipleWe aimed to establish a new AHI by integrating daily mortality risks due to air pollution with thosedue to non-optimum temperature in China.pollutants and non-optimum temperature in 272 Chinese cities from 2013 to 2015.On average, air pollution and non-optimum temperature were associated with 28.23% of daily excess mortality

Keywords: Air pollution     Temperature     Air Health Index     Mortality     Time-series     Risk communication    

Field measurements on microclimate in residential community in Guangzhou, China

Zhuolun CHEN, Lihua ZHAO, Qinglin MENG, Changshan WANG, Yongchao ZHAI, Fei WANG,

Frontiers of Structural and Civil Engineering 2009, Volume 3, Issue 4,   Pages 462-468 doi: 10.1007/s11709-009-0066-6

Abstract: in Guangzhou as an example, we conduct the field measurement of the microclimate at fixed points for airtemperature, relative humidity, black globe temperature and wind speed, etc.

Keywords: microclimate     outdoor thermal environment     air temperature     black globe temperature     wind speed    

Corrigendum to “Multidecadal Trends in Large-Scale Annual Mean SATa Based on CMIP5 Historical Simulations Corrigendum

Nan Xing,Jianping Li,Lanning Wang

Engineering 2017, Volume 3, Issue 3,   Pages 428-428 doi: 10.1016/J.ENG.2017.03.015

An optimized solar-air degree-day method to evaluate energy demand for poultry buildings in different

Yang WANG, Baoming LI

Frontiers of Agricultural Science and Engineering 2020, Volume 7, Issue 4,   Pages 478-489 doi: 10.15302/J-FASE-2019289

Abstract: This study was designed to optimize the degree-day calculation and proposes a solar-air degree-day methodIn this paper, the solar-air degree-day method was proposed, which considers the effects of solar radiationChongqing, Kunming and Guangzhou, were selected to represent different climate zones to determine the solar-airdifferent climates were compared by DeST (Designer’s Simulation Toolkit) simulation and the solar-airThe accuracy of calculating energy requirements was improved by the solar-air degree-day method in the

Keywords: base temperature     energy consumption     solar radiation     orientation     surface color    

simulation of bituminous coal combustion in a full-scale tiny-oil ignition burner: influence of excess air

Zhengqi LI, Chunlong LIU, Xiang ZHANG, Lingyan ZENG, Zhichao CHEN

Frontiers in Energy 2012, Volume 6, Issue 3,   Pages 296-303 doi: 10.1007/s11708-012-0191-0

Abstract: to primary air velocities of 17, 23, 30 and 35 m/s, respectively), which were chosen because they hadThe gas temperatures were high along the center line of the burner for the four excess air ratios.The flame spread to the burner wall and the high-temperature region was enlarged in the radial directionalong the primary air flow direction.The O concentrations for the four excess air ratios were 0.5%, 1.1%, 0.9% and 3.0% at the exit of the

Keywords: numerical simulation     tiny-oil ignition burner     pulverized coal     temperature field    

A Fuzzy Controller With Self-Optimizing Parameters and Its Application in the Central Air-conditioning

Wu Aiguo,Du Chunyan,Song Xiaoqiang

Strategic Study of CAE 2004, Volume 6, Issue 11,   Pages 84-87

Abstract:

On the basis of analyzing characteristics of the central air-conditioning system, a fuzzy controllerwith self-optimizing parameters is proposed and applied into the temperature control of the system.As the temperature of the cooling water and the temperature of the circumstances change, the controller

Keywords: central air-conditioning system     temperature control     fuzzy controller     parameter optimization    

Quasi-period Changes of the Operational Parameters for Hot Oil Pipelines

Cui Hui

Strategic Study of CAE 2006, Volume 8, Issue 1,   Pages 51-53

Abstract:

Subjected to the annual changes of the air temperature, the quasi-period rules of the operationalparameters of the buried hot oil pipelines and the surrounding soil temperature are theoretically presented

Keywords: hot oil pipeline     air temperature     soil environment     quasi-period    

Title Author Date Type Operation

Multidecadal Trends in Large-Scale Annual Mean SATa Based on CMIP5 Historical Simulations and Future

Nan Xing, Jianping Li, Lanning Wang

Journal Article

“Partial pressures” of humid air in wide pressure and temperature ranges

Zidong WANG, Hanping CHEN, Shilie WENG

Journal Article

Improvement of part-load performance of gas turbine by adjusting compressor inlet air temperature and

Journal Article

Experimental and kinetic study on laminar flame speeds of ammonia/syngas/air at a high temperature and

Journal Article

Simulation Research of Temperature Control System in Air-Conditioned Coach

Yu Meichun,Zhang Dengchun

Journal Article

Effect of extrusion temperature on the physical properties of high-silicon aluminum alloy

YANG Fuliang, GAN Weiping, CHEN Zhaoke

Journal Article

An indirect evaporative chiller

Xiaoyun XIE, Yi JIANG,

Journal Article

Industrial-scale investigations on effects of tertiary-air declination angle on combustion and steamtemperature characteristics in a 350-MW supercritical down-fired boiler

Xiaoguang LI, Lingyan ZENG, Hongye LIU, Yao LI, Yifu LI, Yunlong ZHAO, Bo JIAO, Minhang SONG, Shaofeng ZHANG, Zhichao CHEN, Zhengqi LI

Journal Article

The Establishment of a New Air Health Index Integrating the Mortality Risks Due to Ambient Air Pollutionand Non-Optimum Temperature

Qingli Zhang, Renjie Chen, Guanjin Yin, Xihao Du, Xia Meng, Yang Qiu, Haidong Kan, Maigeng Zhou

Journal Article

Field measurements on microclimate in residential community in Guangzhou, China

Zhuolun CHEN, Lihua ZHAO, Qinglin MENG, Changshan WANG, Yongchao ZHAI, Fei WANG,

Journal Article

Corrigendum to “Multidecadal Trends in Large-Scale Annual Mean SATa Based on CMIP5 Historical Simulations

Nan Xing,Jianping Li,Lanning Wang

Journal Article

An optimized solar-air degree-day method to evaluate energy demand for poultry buildings in different

Yang WANG, Baoming LI

Journal Article

simulation of bituminous coal combustion in a full-scale tiny-oil ignition burner: influence of excess air

Zhengqi LI, Chunlong LIU, Xiang ZHANG, Lingyan ZENG, Zhichao CHEN

Journal Article

A Fuzzy Controller With Self-Optimizing Parameters and Its Application in the Central Air-conditioning

Wu Aiguo,Du Chunyan,Song Xiaoqiang

Journal Article

Quasi-period Changes of the Operational Parameters for Hot Oil Pipelines

Cui Hui

Journal Article